Czech manufacturer of light-gauge steel structuresEN 1090 · CE · FPC · material traceability
ENVEO

Off-site panels with a precisely defined build-up.

ENVEO is a higher level of prefabrication. It is neither an automatic part of every structure nor a universal build-up for every building.

Build-up of a prefabricated ENVEO external wall panel
OCELIS SYSTEM

ENVEO off-site wall panels

A higher level of prefabrication combining the OCELIS frame with project-specific boards, insulation, airtightness layers and internal lining.

The ENVEO reference concept uses Rigistabil boards, mineral insulation and the Vario airtightness system from Saint-Gobain. Every build-up must be verified for its specific application.
ENVEO on the Saint-Gobain website
EXTERIORExternal board layerRigistabil 15 mm, depending on the build-up
COREOCELIS + mineral insulationprofiles and insulation according to the design
AIRTIGHTNESSVapour control layer / vapour barrierVario system according to the project
INTERIORInternal board layerRigistabil 12.5 mm
Existing-building retrofit

A new building envelope for an existing frame.

When reinforced-concrete or steel framed buildings are refurbished, ENVEO panels can form a lightweight secondary structure for the external envelope. Depending on the project, they are installed as infill between the primary structural elements or in front of the frame. A high proportion of off-site preparation reduces wet trades and can shorten the time for which the building is exposed to the weather.

ENVEO does not replace the repair or strengthening of the load-bearing frame. Before the panels are designed, the actual condition and geometry, movements, load-bearing capacity, connections, fire performance, thermal and moisture behaviour and acoustic requirements must be verified.
From survey to installation
Survey and dimensional capture

The actual condition, geometry and deviations of the existing structure.

Interface design

Panel position, connections, frame movements, slab edges and openings.

Verified build-up

Fire performance, thermal, acoustic and moisture requirements and the final façade.

Prefabrication and installation

Panel dimensions, work sequence, transport, handling and weather protection.

Conditions of use

A panel is both a product and a logistical unit.

01

Approved build-up

Layers must not be changed without checking fire, acoustic, thermal and structural performance.

02

Transport dimensions

Panel dimensions follow from transport, handling and installation-equipment constraints.

03

Protection during transport

Sensitive layers require a plan for packaging, storage and weather protection.

04

Installation details

Panel joints, corners, openings and penetrations must be resolved in the documentation.

Project enquiry and technical consultation

Let us start with a technical review of your project.

Send plans, sections, site location, required delivery scope and target date. We will propose the next steps.