Czech manufacturer of light-gauge steel structuresEN 1090 · CE · FPC · material traceability
Light-gauge steel structures

A load-bearing system made from precisely prepared profiles.

Behind an apparently simple C or U profile are structural design, a digital manufacturing model, controlled production and coordination of all related layers.

C75–C160 standard profile widths
0.8–1.6 mm standard sheet thicknesses
EN 1090 factory production control system
System principle

A lightweight structure does not mean a simple design.

Light-gauge members offer a high strength-to-weight ratio, but their behaviour is affected by local and distortional buckling, stability, bracing, sheathing build-up and connection details. Every project therefore requires a dedicated calculation.

01

Digital model

The structural geometry and structural design are converted into manufacturing data. The manufacturing model does not replace structural assessment.

02

CNC forming

The line produces profiles in the required lengths, with holes, embossments and markings defined by the data.

03

System connections

Self-drilling screws, anchoring and any heavy-gauge members are designed for the forces transferred and the specific detail.

04

Verified build-up

Fire, acoustic and thermal performance and airtightness are properties of the complete build-up, not of the profile alone.

Materials and durability

How the OCELIS structural system works

Cold-formed galvanized steel profiles create lightweight load-bearing walls, floors, roofs, infill frames and secondary structures.

A coating designation alone does not guarantee a specific service life. The environment, exposure, build-up, cut edges, details and maintenance are decisive.

Article on corrosion protection →
Example wall build-up with a steel profile
Delivery options

The same system, different levels of prefabrication.

01

Manufactured profiles

Members cut to length, punched and marked according to the manufacturing model.

02

Structural kit

Profiles, agreed fasteners and installation documentation.

03

Prefabricated panels

Wall, floor or roof assemblies built in the factory.

04

Structural installation

Installation of the primary load-bearing structure; subsequent layers only when explicitly ordered.

Project enquiry and technical consultation

Let us start with a technical review of your project.

Send plans, sections, site location, required delivery scope and target date. We will propose the next steps.